| Thermal Resistance: |
At a pressure of 14 psi
(appr. 1 kp/cm²) the thermal resistance is 0,19 K/W cm²,
at a pressure of 100 psi (appr. 1 kp/cm²) 0,07 K/W cm².
For example in mounting a peltierelement with an area of 16
cm² the resitance is 0,07 /16 = 0,0043 K/W.
As the pressure
in mounting a peltierelement is higher than 100 psi you can
calculate with 0,004 K/W. |